Page 10 - Environmental Monitoring Presentation
P. 10

Ferrous Scanning









                                                                                                 Sometimes it is necessary to find the position of hidden metals within a concrete
                                                                                                 structure without any intrusive or damaging investigations, making verification
                                                                                                 extremely difficult.

                                                                                                 John F Hunt’s Ferrous Scanner enables the non-destructive inspection of structures,
                                                                                                 identification of objects and rebar, whilst providing concrete cover measurements
                                                                                                 and pinpoint positioning for drilling.


                                                                                                 Scanned data is automatically recorded over lengths of up to 30 metres and
                                                                                                 depths up to 100mm, displaying a clear 2D image for on-the-spot structural analysis
                                                                                                 and depth of cover assessment.

                                                                                                 It is invaluable for:


                                                                                                     •      Rebar verification and analysis of any structures

                                                                                                     •      Checking concrete cover over large areas for structural repair work

                                                                                                     •      Avoiding costly rebar hits and damage caused by cutting through
                                                                                                            structurally significant reinforcement when coring and hammer drilling

                                                                                                     •      The generation of structural assessment reports including statistics and
                                                                                                            visual presentation in 2D/3D views of areas of up to 45 x 45m











      johnfhunt.co.uk                                                                                                                                                info@johnfhunt.co.uk